EN

Sinny Global Website

Products

Solutions

Services

Company

Contact

Temperature Controller

Temperature and Humidity Controller

Solid State Relay

Heat Sink

din Temperature Controller

TX4 temperature controller

TC5 Temperature controller

TC3 Temperature Controller

TCD Temperature Controller

TX2 Temperature controller

TCR Temperature Controller

3-Digit Double Display  PID programmable temperature controller
TC5 Series

3-Digit Double Display PID programmable temperature controller

TC3 LED display screen,100-240VAC wide voltage, 100ms high-speed sampling period and +0.5% display accuracy, supports universal input, output switchable relay /SSR, analog output 0-10v 4-20ma input rs485 temperature controller

Main features Selection Technology Application Download Question Video

Main features

·  Diameter depth 75mm


·  RS485 communication output model: communication protocol Modbus RTU


·K E J N T S R B PT100 CU50 INPUT


·AC DC 100-240V


·Switch between Relay output and SSR drive output


·PID high-precision control algorithm


· Heating/cooling mode selectable


· Thermocouple / RTD / Analog input switch function available

Various Inputs

Various Inputs

Diameter depth 75mm

Diameter depth 75mm

Display error correction

Display error correction

Large character LED display

Large character LED display

RS485 communication model

RS485 communication model

12 alarm modes select

12 alarm modes select

Relay / SSR output switch

Relay / SSR output switch

PID+ control

PID+ control

Auto tuning

Auto tuning

Heating/cooling mode select

Heating/cooling mode select

  • PID+ control

    Stable control

    PID+ control
  • Large character LED display

    Easy to read

    Large character LED display
  • Relay / SSR output switching

    Flexible

    Relay / SSR output switching
  • Various Inputs

    All support

    Various Inputs

Selection

                                

Product

  • programmable temperature controller
  • programmable temperature controller

Specifications

                   

Application

Question

  • Q

    [TC3] How to Switch Relay/SSR Outputs

    A

    Quick switching by shortcut keys:

    In the operation mode

    Press and hold the "↓" and "↑" keys simultaneously for 3 seconds.

  • Q

    [TC3] How do I modify the input type?

    A

    Please operate as follows:

    1. Hold the "SET" key for 2s,The [P-1] page appears, press the "↑" key once, and the [P-2] page appears.

    2. In [P-2], press the "SET" key once, the input specification [INP] page appears, adjust it with the "↑" and "↓" keys.

    After adjusting, hold the "SET" key for 3s to save the parameter and return to run mode.


  • Q

    [TC3] What is the error code for 'HHH' or 'LLL'

    A

    Check the following conditions:

    1. whether the input sensor is damaged

    2. whether the input wiring is correct

    3. Whether the input type of the controller [INP] is matched with the sensor

    4. Whether the error correction [EC] parameter is set correctly

    5. Whether the parameters of the lower range limit [SLL] and upper range limit [SLH] are set correctly.


Video

How can we help? Contact us.

Address:8 Changsheng Road, Liushi Town, Yueqing City, Wenzhou City, Zhejiang Province

Email: sinny@sinny.com

Sales Hotline: +86-577-82238888

Subscribe and get news
Copyright © 2024 Zhejiang Sinny Electric Co., Ltd. All Rights Reserved. Design By Bontop Privacy Policy