Sinny Global Website
China / Chinese
Vietnam / Vietnamese
Global / English
USA / English
Brazil / Portuguese
Mexico / Spanish
Colombia / Spanish
Peru / Spanish
Chile / Spanish
Venezuela / Spanish
Ecuador / Spanish
Global / English
Turkey / Turkish
United Kingdom / English
Spain / Spanish
Portugal / Portuguese
Global / English
Arab / Arabic
Global / English
Temperature Controller
Temperature and Humidity Controller
Solid State Relay
Heat Sink
tx4 din Temperature Controller
tc5 din temperature controller
TX4 temperature controller
TC5 Temperature controller
TC3 Temperature Controller
TCD Temperature Controller
TX2 Temperature controller
TCR Temperature Controller
electronic temperature controller
sub zero temperature controller
process temperature controller
0 10v temperature controller
AC DC temperature controller
4 20ma temperature controller
standard analog input is 4-20ma, and the signal range is 4ma off the line. The voltage signal is 0-10V, with strong anti-interference ability, wide load compatibility and accurate linear correspondence
·4 20ma temperature controller
·types of K E J PT100 CU50 temperature controller
· PID Control
·oven temperature controller
·±0.5 temperature controller
· 12 alarm modes selectable
· TC /RTD 4-20ma input
· Heating/cooling mode selectable
·relay ssr output
PID Control
Diameter depth 75mm
4-20mA/0-10V
Heating/cooling mode select
HD LED display
Temperature unit switch
12 alarm modes select
Display error correction
Auto tuning
RS485 communication model
Relay / SSR output switch
Bright
Meet the requirements of different working conditions
Global adaptation
All support
Communication protocol Modbus RTU
Stable control
Provide a variety of solutions
Global adaptation
Quick switching by shortcut keys:
In the operation mode
Press and hold the "↓" and "↑" keys simultaneously for 3 seconds.
Please operate as follows:
1. Hold the "SET" key for 2s,The [P-1] page appears, press the "↑" key once, and the [P-2] page appears.
2. In [P-2], press the "SET" key once, the input specification [INP] page appears, adjust it with the "↑" and "↓" keys.
After adjusting, hold the "SET" key for 3s to save the parameter and return to run mode.
Check the following conditions:
1. whether the input sensor is damaged
2. whether the input wiring is correct
3. Whether the input type of the controller [INP] is matched with the sensor
4. Whether the error correction [EC] parameter is set correctly
5. Whether the parameters of the lower range limit [SLL] and upper range limit [SLH] are set correctly.
Address:8 Changsheng Road, Liushi Town, Yueqing City, Wenzhou City, Zhejiang Province
Email: sinny@sinny.com
Sales Hotline: +86-577-82238888