Temperature Controller
Temperature and Humidity Controller
Solid State Relay
Heat Sink
din Temperature Controller
TX4 temperature controller
TC5 Temperature controller
TC3 Temperature Controller
TCD Temperature Controller
TX2 Temperature controller
TCR Temperature Controller
TC5 pid digital display temperature controller features a wide voltage range of 100-240v and supports various thermocouple/Rtd/analog signal inputs.The output can freely switch relays/SSRS, supporting single and dual alarm functions and a temperature controller with 4-20ma 0-10v input
· Diameter depth 75mm
· HD white light display
· Thermocouple / RTD / Analog input switch function available
· Fahrenheit / Celsius unit switch function available
· RS485 communication output model: communication protocol Modbus RTU
· Switch between Relay output and SSR drive output
· Enhanced PID+ control algorithm
· Automatic calculation function
· Display error correction function
· Heating/cooling mode selectable
· 12 alarm modes selectable
·pid digital type K E J PT100 CU50 ac dc temperature controller
·100-240volt 24v TC RTD Temperature Controller
·Rs485 modbus temperature controller
·0-10v output thermistor Temperature Controller
·4-20ma input 220v digital temperature controller
Diameter depth 75mm
Various Inputs
Temperature unit switch
HD LED display
RS485 communication model
PID+ control
Relay / SSR output switch
12 alarm modes select
Heating/cooling mode select
Display error correction
Auto tuning
Bright
Meet the requirements of different working conditions
Global adaptation
All support
Communication protocol Modbus RTU
Flexible
Provide a variety of solutions
Stable control
Quick switching by shortcut keys:
In the operation mode
Press and hold the "↓" and "↑" keys simultaneously for 3 seconds.
Please operate as follows:
1. Hold the "SET" key for 2s,The [P-1] page appears, press the "↑" key once, and the [P-2] page appears.
2. In [P-2], press the "SET" key once, the input specification [INP] page appears, adjust it with the "↑" and "↓" keys.
After adjusting, hold the "SET" key for 3s to save the parameter and return to run mode.
Check the following conditions:
1. whether the input sensor is damaged
2. whether the input wiring is correct
3. Whether the input type of the controller [INP] is matched with the sensor
4. Whether the error correction [EC] parameter is set correctly
5. Whether the parameters of the lower range limit [SLL] and upper range limit [SLH] are set correctly.
Address:8 Changsheng Road, Liushi Town, Yueqing City, Wenzhou City, Zhejiang Province
Email: sinny@sinny.com
Sales Hotline: +86-577-82238888