Temperature Controller

Temperature and Humidity Controller

Solid State Relay

Heat Sink

tx4 din Temperature Controller

tc5 din temperature controller

1 16 Din Temperature Controller

4 1 din temperature controller

1 4 din temperature controller

1 8 din temperature controller

1 2 din temperature controller

industrial temperature controller
best temperature controller

industrial temperature controller

Main features Selection Technology Application Download Question Video

Main features

·PID process programmable temp controller

·types of K E J PT100 CU50 digital temperature controller

· Heating/cooling mode selectable Temperature control

·±0.5 precision temperature controller

· Thermocouple / RTD input switch function available

· Shell made of Japan's high-grade PC material, V-0 flame retardant grade

· Compact, space-saving design with 50mm depth:30% rear-length size reduction compared to similar-sized models from Sinny

· Shell made of Japan's high-grade PC material, V-0 flame retardant grade

· Thermocouple / RTD input switch function available

· Fahrenheit / Celsius unit switch function available

· Switch between Relay output and SSR drive output

· Enhanced PID+ control algorithm

· Automatic calculation function

· Display error correction function

· Heating/cooling mode selectable

·1 2 din temperature controller


PID+ control

PID+ control

Temperature unit switch

Temperature unit switch

TC / RTD input switch

TC / RTD input switch

Diameter depth 50mm

Diameter depth 50mm

Display error correction

Display error correction

12 alarm modes select

12 alarm modes select

LED display

LED display

Auto tuning

Auto tuning

Heating/cooling mode   select

Heating/cooling mode select

Relay / SSR output switch

Relay / SSR output switch

Selection

                                               

Product

Specifications

                                  

Application

Question

  • Q

    [TX4] How to Switch Relay/SSR Outputs

    A

    Quick switching by shortcut keys:

    In the operation mode

    Press and hold the "↓" and "↑" keys simultaneously for 3 seconds.

  • Q

    [TX4] How do I modify the input type?

    A

    Please operate as follows:

    1. Hold the "SET" key for 2s,The [P-1] page appears, press the "↑" key once, and the [P-2] page appears.

    2. In [P-2], press the "SET" key once, the input specification [INP] page appears, adjust it with the "↑" and "↓" keys.

    After adjusting, hold the "SET" key for 3s to save the parameter and return to run mode.


  • Q

    [TX4] What is the error code for 'HHHH' or 'LLLL'

    A

    Check the following conditions:

    1. whether the input sensor is damaged

    2. whether the input wiring is correct

    3. Whether the input type of the controller [INP] is matched with the sensor

    4. Whether the error correction [EC] parameter is set correctly

    5. Whether the parameters of the lower range limit [SLL] and upper range limit [SLH] are set correctly.


Video