Temperature Controller
Temperature and Humidity Controller
Solid State Relay
Heat Sink
tx4 din Temperature Controller
tc5 din temperature controller
1 16 din Temperoture Controller
1 4 din Temperoture Control
4 1 din temperoture controller
1 8 din temperoture controller
1 2 din temperoture controller
TC5 4 1 din temperature controller features multiple input and output modes, with a wide voltage range of 100-240v, universal TC and RTD inputs, as well as linear current and voltage inputs. It has a high precision of ±0.5%. Conventional outputs only include Relay and SSR, but the TC5 also offers current and voltage outputs. Of course, the alarm and communication RS485 output are also satisfactory.
· RS485 Temperature Controller
· 0-10v output temperature controller
· 1 16 din Temperoture Controller
· pid temperature controller rs485
· K E J PT100 CU50 0-10v 4-20ma RS485 output
· Diameter depth 75mm
· 12 alarm modes selectable
· HD white light display
· digital temperature controller
Diameter depth 75mm
HD LED display
Auto tuning
Various Inputs
PID+ control
Temperature unit switch
Heating/cooling mode select
Various output model
Display error correction
12 alarm modes select
Relay / SSR output switch
RS485 communication model
Meet the requirements of different working conditions
Bright
Flexible
All support
Communication protocol Modbus RTU
Provide a variety of solutions
Global adaptation
Stable control
Quick switching by shortcut keys:
In the operation mode
Press and hold the "↓" and "↑" keys simultaneously for 3 seconds.
Please operate as follows:
1. Hold the "SET" key for 2s,The [P-1] page appears, press the "↑" key once, and the [P-2] page appears.
2. In [P-2], press the "SET" key once, the input specification [INP] page appears, adjust it with the "↑" and "↓" keys.
After adjusting, hold the "SET" key for 3s to save the parameter and return to run mode.
Check the following conditions:
1. whether the input sensor is damaged
2. whether the input wiring is correct
3. Whether the input type of the controller [INP] is matched with the sensor
4. Whether the error correction [EC] parameter is set correctly
5. Whether the parameters of the lower range limit [SLL] and upper range limit [SLH] are set correctly.
Address:8 Changsheng Road, Liushi Town, Yueqing City, Wenzhou City, Zhejiang Province