Sinny Global Website
China / Chinese
Vietnam / Vietnamese
Global / English
USA / English
Brazil / Portuguese
Mexico / Spanish
Colombia / Spanish
Peru / Spanish
Chile / Spanish
Venezuela / Spanish
Ecuador / Spanish
Global / English
Turkey / Turkish
United Kingdom / English
Spain / Spanish
Portugal / Portuguese
Global / English
Arab / Arabic
Global / English
Temperature Controller
Temperature and Humidity Controller
Solid State Relay
Heat Sink
tx4 din Temperature Controller
tc5 din temperature controller
1 16 din Temperoture Controller
1 4 din Temperoture Control
4 1 din temperoture controller
1 8 din temperoture controller
1 2 din temperoture controller
TC5 1 8 din temperature controller is highly accurate in temperature control for both cooling and heating. By setting certain parameters and using a temperature sensor in conjunction with the PID algorithm, it can control the mechanical temperature range, allowing you to switch between Celsius (℃) and Fahrenheit (℉) to achieve the desired effect.
·1 8 din temperoture controller
· Diameter depth 75mm
· HD white light display
· Thermocouple / RTD / Analog input
· Fahrenheit / Celsius unit switch function available
· RS485 communication output model: communication protocol Modbus RTU
· Relay output and SSR drive output
· pid control
· Automatic calculation function
· Display error correction function
· Heating/cooling mode selectable
· 12 alarm modes selectable
Diameter depth 75mm
HD LED display
Auto tuning
Various Inputs
PID+ control
Temperature unit switch
Heating/cooling mode select
Various output model
Display error correction
12 alarm modes select
Relay / SSR output switch
RS485 communication model
Meet the requirements of different working conditions
Bright
Flexible
All support
Communication protocol Modbus RTU
Provide a variety of solutions
Global adaptation
Stable control
Quick switching by shortcut keys:
In the operation mode
Press and hold the "↓" and "↑" keys simultaneously for 3 seconds.
Please operate as follows:
1. Hold the "SET" key for 2s,The [P-1] page appears, press the "↑" key once, and the [P-2] page appears.
2. In [P-2], press the "SET" key once, the input specification [INP] page appears, adjust it with the "↑" and "↓" keys.
After adjusting, hold the "SET" key for 3s to save the parameter and return to run mode.
Check the following conditions:
1. whether the input sensor is damaged
2. whether the input wiring is correct
3. Whether the input type of the controller [INP] is matched with the sensor
4. Whether the error correction [EC] parameter is set correctly
5. Whether the parameters of the lower range limit [SLL] and upper range limit [SLH] are set correctly.
Address:8 Changsheng Road, Liushi Town, Yueqing City, Wenzhou City, Zhejiang Province
Email: sinny@sinny.com
Sales Hotline: +86-577-82238888